I-Sinomeasure Multi-parameter analyzer
Into | Isalathiso | Ixabiso |
Inkqubo | amandla okusebenza | (220±22)V AC,(50±1)Hz |
Amandla | 30W | |
Ubungakanani bekhabhinethi | 800mm * 506mm * 180mm (uguqulelo oluqhelekileyo) | |
Ubunzima | malunga ne-15Kg | |
Ubushushu bokugcina | 4℃~+50℃ | |
Ubushushu bokusebenza | 4℃~+50℃ / -25℃~+50℃(ukhetho lolawulo lobushushu kwimodyuli yokufudumeza umkhenkce) | |
Ukufuma okusebenzayo | ≤95%RH (akukho lujiko) | |
Ukuhamba kokungena | 500~1000 mL/min | |
Uxinzelelo lokungena | < 3kg/cm³ | |
Ujongano lonxibelelwano | RS485 Modbus RTU unxibelelwano protocol + interface wireless | |
Unxunguphalo | Uluhlu | 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU |
Isigqibo | 0.001NTU | |
Umda wokubona osezantsi | 0.02NTU;0.1NTU(0-4000NTU) | |
Zero drift | ≤1.5% | |
Uzinzo olubonisa | ≤1.5% | |
Ukuchaneka | 2% okanye ±0.02NTU;5% okanye 0.5NTU (0-4000NTU) | |
Ukuphindaphinda | ≤3% | |
Ixesha lokuphendula | ≤60s | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezi-3-12 (kuxhomekeke kumgangatho wamanzi kwindawo) | |
Intsalela yeklorine/iklorini diokside | Uluhlu | 0-5mg/L / 0-20mg/L |
Isigqibo | 0.01mg/L | |
Umda wokubona osezantsi | 0.05mg/L | |
Ukuchaneka | ±0.05mg/L okanye ±5% (impazamo yokuthelekisa iDPD ±10%) | |
Ixesha lokuphendula | ≤120 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezi-1-3 okanye ulungelelwaniso lweveki, iinyanga ezi-3-6 zokutshintsha izinto ezisetyenziswayo | |
PH /ORP(uyazikhethela) | Uluhlu | 0-14pH, ±2000mV (ORP) |
Isigqibo | 0.01pH, ±1mV(ORP) | |
Ukuchaneka | ±0.1pH, ±20mV(ORP)okanye ±2% | |
Ukuphindaphinda | ±0.1pH, ±10mV(ORP) | |
Ixesha lokuphendula | ≤60 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezi-1-3 | |
Ubushushu | Uluhlu | -20℃ – 85℃ |
Isigqibo | 0.1℃ | |
Ukuchaneka | ±0.5℃ | |
Ukuphindaphinda | ≤0.5℃ | |
Ixesha lokuphendula | ≤25 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezili-12 | |
Ukuqhuba (Ngokuzithandela) | Uluhlu | 1-2000uS / cm / 1 ~ 200mS / m |
Ukuchaneka | ±1.5%FS | |
Ukuphindaphinda | ≤0.5%FS | |
Ixesha lokuphendula | ≤30 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | 3-6 iinyanga | |
Ioksijini enyibilikisiweyo (Ngokhetho) | Uluhlu | 0-20mg/L |
Ukuchaneka | ±0.3mg/L | |
Ukuphindaphinda | ≤±1.5% | |
Ixesha lokuphendula | ≤30 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezi-1-3 | |
Ukwandiswa kwezibuko | Uhlobo lwezibuko | RS485, 4-20mA, 0-5V |
Into | Isalathiso | Ixabiso |
Inkqubo | amandla okusebenza | (220±22)V AC,(50±1)Hz |
Amandla | 30W | |
Ubungakanani bekhabhinethi | 800mm * 506mm * 180mm (uguqulelo oluqhelekileyo) | |
Ubunzima | malunga ne-15Kg | |
Ubushushu bokugcina | 4℃~+50℃ | |
Ubushushu bokusebenza | 4℃~+50℃ / -25℃~+50℃(ukhetho lolawulo lobushushu kwimodyuli yokufudumeza umkhenkce) | |
Ukufuma okusebenzayo | ≤95%RH (akukho lujiko) | |
Ukuhamba kokungena | 500~1000 mL/min | |
Uxinzelelo lokungena | < 3kg/cm³ | |
Ujongano lonxibelelwano | RS485 Modbus RTU unxibelelwano protocol + interface wireless | |
Unxunguphalo | Uluhlu | 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU |
Isigqibo | 0.001NTU | |
Umda wokubona osezantsi | 0.02NTU;0.1NTU(0-4000NTU) | |
Zero drift | ≤1.5% | |
Uzinzo olubonisa | ≤1.5% | |
Ukuchaneka | 2% okanye ±0.02NTU;5% okanye 0.5NTU (0-4000NTU) | |
Ukuphindaphinda | ≤3% | |
Ixesha lokuphendula | ≤60s | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezi-3-12 (kuxhomekeke kumgangatho wamanzi kwindawo) | |
Intsalela yeklorine/iklorini diokside | Uluhlu | 0-5mg/L / 0-20mg/L |
Isigqibo | 0.01mg/L | |
Umda wokubona osezantsi | 0.05mg/L | |
Ukuchaneka | ±0.05mg/L okanye ±5% (impazamo yokuthelekisa iDPD ±10%) | |
Ixesha lokuphendula | ≤120 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezi-1-3 okanye ulungelelwaniso lweveki, iinyanga ezi-3-6 zokutshintsha izinto ezisetyenziswayo | |
PH /ORP(uyazikhethela) | Uluhlu | 0-14pH, ±2000mV (ORP) |
Isigqibo | 0.01pH, ±1mV(ORP) | |
Ukuchaneka | ±0.1pH, ±20mV(ORP)okanye ±2% | |
Ukuphindaphinda | ±0.1pH, ±10mV(ORP) | |
Ixesha lokuphendula | ≤60 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezi-1-3 | |
Ubushushu | Uluhlu | -20℃ – 85℃ |
Isigqibo | 0.1℃ | |
Ukuchaneka | ±0.5℃ | |
Ukuphindaphinda | ≤0.5℃ | |
Ixesha lokuphendula | ≤25 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezili-12 | |
Ukuqhuba (Ngokuzithandela) | Uluhlu | 1-2000uS / cm / 1 ~ 200mS / m |
Ukuchaneka | ±1.5%FS | |
Ukuphindaphinda | ≤0.5%FS | |
Ixesha lokuphendula | ≤30 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | 3-6 iinyanga | |
Ioksijini enyibilikisiweyo (Ngokhetho) | Uluhlu | 0-20mg/L |
Ukuchaneka | ±0.3mg/L | |
Ukuphindaphinda | ≤±1.5% | |
Ixesha lokuphendula | ≤30 imizuzwana | |
Ixesha lolondolozo elicetyiswayo | Iinyanga ezi-1-3 | |
Ukwandiswa kwezibuko | Uhlobo lwezibuko | RS485, 4-20mA, 0-5V |
-
Intshayelelo
I-Multi-parameter analyser inokusetyenziswa ngokubanzi kwiindawo zokubonelela ngamanzi ezidolophini okanye ezilalini, uthungelwano lwemibhobho yamanzi ompompo, unikezelo lwamanzi lwempompo yesibini, iitephu zabasebenzisi, amadama okuqubha angaphakathi, ukubeka iliso kwi-Intanethi komgangatho wamanzi njengezixhobo ezinkulu zokucoca amanzi kunye ngqo. Amanzi okusela sisixhobo esiyimfuneko sohlalutyo lwe-intanethi kwimimandla yolawulo lwenkqubo yokuveliswa kwezityalo zamanzi, ukugcinwa kwamanzi kunye nolawulo lwamanzi, kunye nolawulo lococeko.